Refer a Patient Request an Appointment
Adel M. Malek, MD, PhDNeurovascular Surgery · Boston

2000 · Devices & clinical

Balloon-assist technique for endovascular coil embolization of geometrically difficult intracranial aneurysms

Malek AM, Halbach VV, Phatouros CC, Lempert TE, Meyers PM, Dowd CF, Higashida RT.

Neurosurgery 46(6):1397-406; discussion 1406-7, 2000.

PMID 10834645 · DOI 10.1097/00006123-200006000-00022

In plain language

Some brain aneurysms have a wide opening (neck) or an awkward shape that makes it hard to keep coils inside them. In the balloon-assist technique, a small balloon is inflated across the neck while coils are placed, but there was little data on how well and how safely it works.

This study treated 22 aneurysms in 20 patients, most on the carotid artery just inside the skull. Technical success was achieved in 17 of 22 cases, with aneurysms 97% filled at the end of treatment and stable at follow-up averaging 10.3 months. Three temporary complications occurred (13.6%), with no deaths and no lasting harm from the procedure.

The authors conclude that the method, though more complex, widens the range of aneurysms that can be treated with coils.

A plain-language summary for patients and families. It is not medical advice, and individual results vary.

Abstract

Objective

The balloon-assist or neck-remodeling technique is an adjunctive method devised for the endovascular coil embolization of aneurysms characterized by a wide neck or unfavorable geometric features. Since its initial description, there have been few data to corroborate its utility, efficacy, and safety in aneurysm embolization.

Methods

Twenty patients (19 female patients and 1 male patient) with 22 aneurysms (19 unruptured aneurysms and 3 ruptured aneurysms) underwent balloon-assisted coil embolization. The balloon-assist technique was performed in the same treatment session after conventional coil embolization had failed in 55% of cases (12 of 22 cases) and was the primary treatment in 45% of cases. The majority of aneurysms were located in the supraclinoid carotid artery (13 paraophthalmic and 3 superior hypophyseal aneurysms). The mean angiographic measurements included a fundus of 8.7 +/- 3.7 mm, a neck of 5.3 +/- 2.2 mm, and a comparatively unfavorable fundus/neck ratio of 1.33 +/- 0.23.

Results

Technical success was achieved in 77% of cases (17 of 22). The rate of aneurysm obliteration at the end of the procedures was 97 +/- 3.8%. Angiographic follow-up data (mean follow-up period, 10.3 mo) obtained for 89% of the treated aneurysms (15 of 17) confirmed stable mean occlusion of 97.8 +/- 3.8%. Technical complications included two cases of asymptomatic distal vessel thromboembolism, which resolved angiographically within 24 hours, and one case of intraprocedural rupture of an arteriovenous malformation-related feeder artery aneurysm, which resulted in no neurological deficits and required no further treatment (transient complication rate, 13.6%; 3 of 22 cases). There were no deaths and no procedure-related 30-day or permanent morbidity.

Conclusion

The balloon-assist method of coil embolization is characterized by promising intermediate-term angiographic and clinical outcomes and acceptable morbidity and mortality rates. Although this adjunctive method requires the use of an additional microcatheter and consequently involves a higher level of technical complexity, it extends the range of aneurysms that can be successfully treated with electrolytically detachable coils via an endovascular approach.

Abstract as indexed in PubMed (PMID 10834645). Copyright the publisher.

Cite this paper

Malek AM, Halbach VV, Phatouros CC, Lempert TE, Meyers PM, Dowd CF, Higashida RT. Balloon-assist technique for endovascular coil embolization of geometrically difficult intracranial aneurysms. Neurosurgery 46(6):1397-406; discussion 1406-7. 2000. doi:10.1097/00006123-200006000-00022 PMID: 10834645.