Refer a Patient Request an Appointment
Adel M. Malek, MD, PhDNeurovascular Surgery · Boston

1997 · Hemodynamics & imaging

Quantitative densitometric analysis using a commercially available handheld CCD digital camera

Malek AM, Izumo S, Alper SL.

Biotechniques 22(6):1150-3, 1997.

PMID 9187767

In plain language

Laboratory experiments often produce X-ray films whose darkness must be measured to compare amounts of a substance, a process called densitometry. This study tested whether an ordinary handheld digital camera could do the job.

The camera photographed films lit from behind, and the images were analyzed on a personal computer. Using a test pattern of radioactive dots made by serial dilution, the camera gave results comparable to a desktop scanner, and both matched phosphor imaging, another measurement method, over the film's 16-fold linear range.

The authors suggest that handheld digital cameras are a useful addition to laboratory measurement tools.

A plain-language summary for patients and families. It is not medical advice, and individual results vary.

Abstract

We describe here a novel method that relies on a digital imaging device to perform densitometric quantitation of radiographs in the laboratory setting. Using fluorescent back-illumination and appropriate exposure settings, a commercially available handheld charge-coupled device (CCD) digital camera is used to acquire the image of the radiograph. Following acquisition, the image is downloaded by means of a serial interface to a personal computer. There, it is analyzed to ensure that the series of pixel intensities lie within the linear range and then quantitated using two-dimensional integration with local background substraction. Using a linear dot blot established with serial dilution of 32P and imaging with standard radiographic film, we found that images acquired using the handheld digital camera were comparable to those input with a desktop scanner in transmittance mode. Quantitative densitometric analysis showed similar linear results between the digital camera and the desktop scanner over the 16-fold linear response of the radiographic film, both of which were comparable to phosphor imaging over that limited range. These findings demonstrate that the ever-improving technology of handheld digital imaging should be added to the repertoire of techniques for quantitative densitometry.

Abstract as indexed in PubMed (PMID 9187767). Copyright the publisher.

Cite this paper

Malek AM, Izumo S, Alper SL. Quantitative densitometric analysis using a commercially available handheld CCD digital camera. Biotechniques 22(6):1150-3. 1997. PMID: 9187767.